carte-bleue Hardware Software Agrar Bau und Handwerk dhl dpd Elektronik und Elektrotechnik fax Hotel Gastronomie Betriebs und Lagerausstattung Arbeitsschutz gls hermes Haus und Gebaeudetechnik hook storno cog Industriebedarf info mail mastercard notepad Buerobedarf ok paiement_d_avance_icon paypal phone rechnung sale search sofortueberweisung tnt ups visa Vorkasse Pagamento anticipato Vooruitbetaling iDeal voucher Warenkorb
Checkout
saved
Free
Shipping
saved

PCE Instruments Air Sampler, PCE-AS1

Ships from manufacturer
Ships from manufacturer
PCE Instruments Air Sampler, PCE-AS1
PCE Instruments Air Sampler, PCE-AS1
PCE Instruments Air Sampler, PCE-AS1
     
  • Number of micropores in the collecting head: 589
  • Hole diameter of the micropores: 0.8 mm / 0.03"
  • Battery: 6400 mA
  • Sample throughput: 100liters per minute (l/min) or 3.53 cubic feet per minute
  • Flowrate at measuring head: 0.38 l/min
  • Automatic control of the measuring volume: 10- 6000 liters
  • Dimensionof plate: ø 70 - 90 x 15 mm / ø 2.76 x 3.54 x 0.59 inches
  • Datastorage: max.99 parameters and 2000 measurement values
  • Dimensions: ø 120 x 300 mm / ø 4.72 x 11.81 inches
  • Standards: ISO14698-1
  • Weight: 2.6kg / 5.73 lb
PCE Instruments Air Sampler, PCE-AS1, 4250348713056 PCE-AS1 Air Sampler Portable 100 lpm aerosol...more
PCE Instruments Air Sampler, PCE-AS1, 4250348713056

PCE-AS1 Air Sampler
Portable 100 lpm aerosol hygiene monitoring device for airborne microbial, microbiological, bacterial, mold, fungi and virus analysisPCE-AS1 is an air sampling meter used to assess microbiological pollution and monitor hygiene. Designed for use in hospitals, clean rooms and food and beverage, cosmetics and pharmaceutical production facilities, the PCE-AS1 air sampler meets the latest requirements for devices used for airborne microbial analysis. Optional ISO calibration lab certificate as an accessory.

The PCE-AS1 air sampler uses the aerosol impaction principle or Andersen collision principle to assess air quality. The air taken in at the top of the instrument is pulled through 300 micropores and the resulting laminar air flow is directed onto the surface of an agar petri dish. When the sampling cycle is complete, the petri dish is removed and incubated. The bacterial and fungal counts can then be assessed in accordance with USP 797 and CAG-009 guidance.The collecting head should be sterilized in an autoclave at 121° C for 30 minutes (sterilization with a cloth with 75% alcohol is also possible.) The petri dish should also be sterilized with 75% alcohol.
  • Backlit LCD
  • Memory for up to 99 parameters
  • Sterilizable collecting head
  • Adjustable volumes of up to 6000 l
  • Powerful battery
  • Use of standard petri dishes
Delivery Scope
  • 1 x Air sampler PCE-AS1
  • 1 x adapter for glass petri dishes with calibration attachment
  • 1 x power plug
  • 1 x carrying case
  • 1 x instruction manual
Restrictions
>
WARNING: Cancer and Reproductive Harm. For more information go to: www.P65Warnings.ca.gov
Hazardous material
You will receive your personal $15 voucher with your order confirmation
Voucher
Spend over $200 and get a $15 voucher for your next order
$15 Voucher badge background image
$4,331.70 * $5,977.75 * (27.54% Saved)

plus VAT Free shipping

Free shipping!

Delivery time 3-5 business days

Secure payment Secure payment
PCE Instruments Air Sampler, PCE-AS1
PCE Instruments Air Sampler, PCE-AS1
Add this item and enjoy fast shipping
Badge-Fire Popular product! About people already have it in their shopping cart
Badge-Package Free SHIPPING - Directly from the manufacturer!
Badge-Medal Top seller in the store!
Proven product
Proven product
Top international brands already trust us!
intel
Apple
John Deere
Netflix
Tesla
AT&T
cvs health
Caterpillar
Nike
Walmart
Secure shopping
Secure shopping
  • Free shipping from $50
  • Fast delivery
  • Your personal buyer protection
  • Number of micropores in the collecting head: 589
  • Hole diameter of the micropores: 0.8 mm / 0.03"
  • Battery: 6400 mA
  • Sample throughput: 100liters per minute (l/min) or 3.53 cubic feet per minute
  • Flowrate at measuring head: 0.38 l/min
  • Automatic control of the measuring volume: 10- 6000 liters
  • Dimensionof plate: ø 70 - 90 x 15 mm / ø 2.76 x 3.54 x 0.59 inches
  • Datastorage: max.99 parameters and 2000 measurement values
  • Dimensions: ø 120 x 300 mm / ø 4.72 x 11.81 inches
  • Standards: ISO14698-1
  • Weight: 2.6kg / 5.73 lb
PCE Instruments Air Sampler, PCE-AS1, 4250348713056 PCE-AS1 Air Sampler Portable 100 lpm aerosol...more
PCE Instruments Air Sampler, PCE-AS1, 4250348713056

PCE-AS1 Air Sampler
Portable 100 lpm aerosol hygiene monitoring device for airborne microbial, microbiological, bacterial, mold, fungi and virus analysisPCE-AS1 is an air sampling meter used to assess microbiological pollution and monitor hygiene. Designed for use in hospitals, clean rooms and food and beverage, cosmetics and pharmaceutical production facilities, the PCE-AS1 air sampler meets the latest requirements for devices used for airborne microbial analysis. Optional ISO calibration lab certificate as an accessory.

The PCE-AS1 air sampler uses the aerosol impaction principle or Andersen collision principle to assess air quality. The air taken in at the top of the instrument is pulled through 300 micropores and the resulting laminar air flow is directed onto the surface of an agar petri dish. When the sampling cycle is complete, the petri dish is removed and incubated. The bacterial and fungal counts can then be assessed in accordance with USP 797 and CAG-009 guidance.The collecting head should be sterilized in an autoclave at 121° C for 30 minutes (sterilization with a cloth with 75% alcohol is also possible.) The petri dish should also be sterilized with 75% alcohol.
  • Backlit LCD
  • Memory for up to 99 parameters
  • Sterilizable collecting head
  • Adjustable volumes of up to 6000 l
  • Powerful battery
  • Use of standard petri dishes
Delivery Scope
  • 1 x Air sampler PCE-AS1
  • 1 x adapter for glass petri dishes with calibration attachment
  • 1 x power plug
  • 1 x carrying case
  • 1 x instruction manual
Restrictions
>