Manufacturer: |
Cendrex
|
Supplier number: | PFI 22X30 |
UPC: | 764728132251 |
Technical specs:
- Dimensions: 22 x 30 inches
- Dimensions: 558 x 762 mm
- Weight: 31.9 lbs
- Weight: 14.5 Kg
- Number of locks: 1
Cendrex Fire-Rated Insulated Access Door with Exposed Flange, 22 x 30", PFI 22X30, 764728132251...more
Cendrex Fire-Rated Insulated Access Door with Exposed Flange, 22 x 30", PFI 22X30, 764728132251
The fire-rated insulated access door can be installed on fire-rated walls and ceilings.
The fire-rated insulated access door can be installed on fire-rated walls and ceilings.
- Material: 20-gauge galvanneal steel door and 16-gauge cold rolled steel frame
- Hinge: Continuous piano hinge. Hinge location: Hinges must be located on the second dimension (height).
- Locking mechanism: Self-latching tool-key operated slam latch and ring-operated slam latch, both included.
- Flange: 1" exposed flange, made of cold rolled steel
- Frame: 2½ " in depth, made of cold rolled steel
- Rough opening: Door sizes + ¼" or + 6mm
- Insulation: 2" thick fire rated mineral wool
- Inside panel release: Mechanisms to allow panels to open from inside, standard on all doors over 12" X 12 inches.
- Finish: High quality white powder coat primer.
- Packaging: Individually wrapped, 1 door per box.
- Vertical wall assemblies: Fire rated access doors, for vertical use, are subject to the following:
- Vertical wall assemblies: Fire rated access doors, for vertical use, are subject to the following:
- Certification: UL 10B (2009), NFPA 252 (2012), CAN/ULC S104 (2010).
- Rating Achieved: 3 hours, neutral/negative pressure
- Maximum size: 48" x 48" (1219mm x 1219mm), maximum area of 2304 in², tolerance on height and width limitation is more or less 3" (76mm) as long as the area does not exceed 2304 in².
- Temperature rise: 250°F (121°C) after 30 minutes and 450°F (232°C) after 60 minutes.
- Horizontal ceiling assemblies: Fire rated access doors, for horizontal use, are subject to the following:
- Horizontal ceiling assemblies: Fire rated access doors, for horizontal use, are subject to the following:
- Certification: ASTM E119 (2012), CAN/ULC S101 (2007)
- Rating Achieved: 3 hours in non-combustible construction and 1 hour in combustible construction
- Maximum size: 24"X36" (610 mm X 914 mm) (hinges and latches on the side of 36"), tolerance on dimension limitations are more or less 3" (76 mm) as long as the area does not exceed 864 in².
- Temperature rise: Within allowable per ASTM E119 and CAN/ULC S101
CX-118
You will receive your personal $15 voucher with your order confirmation
Spend over $200 and get a $15 voucher for your next order
$15
$278.59 *
$283.04 *
(1.57% Saved)
Free shipping!
Delivery time 3-6 business days

Cendrex Fire-Rated Insulated Access Door with Exposed Flange, 22 x 30", PFI 22X30
Add this item and enjoy fast shipping
Proven product
Top international brands already trust us!










Secure shopping
- Free shipping from $50
- Fast delivery
- Your personal buyer protection
Manufacturer: |
Cendrex
|
Supplier number: | PFI 22X30 |
UPC: | 764728132251 |
Technical specs:
- Dimensions: 22 x 30 inches
- Dimensions: 558 x 762 mm
- Weight: 31.9 lbs
- Weight: 14.5 Kg
- Number of locks: 1
Cendrex Fire-Rated Insulated Access Door with Exposed Flange, 22 x 30", PFI 22X30, 764728132251...more
Cendrex Fire-Rated Insulated Access Door with Exposed Flange, 22 x 30", PFI 22X30, 764728132251
The fire-rated insulated access door can be installed on fire-rated walls and ceilings.
The fire-rated insulated access door can be installed on fire-rated walls and ceilings.
- Material: 20-gauge galvanneal steel door and 16-gauge cold rolled steel frame
- Hinge: Continuous piano hinge. Hinge location: Hinges must be located on the second dimension (height).
- Locking mechanism: Self-latching tool-key operated slam latch and ring-operated slam latch, both included.
- Flange: 1" exposed flange, made of cold rolled steel
- Frame: 2½ " in depth, made of cold rolled steel
- Rough opening: Door sizes + ¼" or + 6mm
- Insulation: 2" thick fire rated mineral wool
- Inside panel release: Mechanisms to allow panels to open from inside, standard on all doors over 12" X 12 inches.
- Finish: High quality white powder coat primer.
- Packaging: Individually wrapped, 1 door per box.
- Vertical wall assemblies: Fire rated access doors, for vertical use, are subject to the following:
- Vertical wall assemblies: Fire rated access doors, for vertical use, are subject to the following:
- Certification: UL 10B (2009), NFPA 252 (2012), CAN/ULC S104 (2010).
- Rating Achieved: 3 hours, neutral/negative pressure
- Maximum size: 48" x 48" (1219mm x 1219mm), maximum area of 2304 in², tolerance on height and width limitation is more or less 3" (76mm) as long as the area does not exceed 2304 in².
- Temperature rise: 250°F (121°C) after 30 minutes and 450°F (232°C) after 60 minutes.
- Horizontal ceiling assemblies: Fire rated access doors, for horizontal use, are subject to the following:
- Horizontal ceiling assemblies: Fire rated access doors, for horizontal use, are subject to the following:
- Certification: ASTM E119 (2012), CAN/ULC S101 (2007)
- Rating Achieved: 3 hours in non-combustible construction and 1 hour in combustible construction
- Maximum size: 24"X36" (610 mm X 914 mm) (hinges and latches on the side of 36"), tolerance on dimension limitations are more or less 3" (76 mm) as long as the area does not exceed 864 in².
- Temperature rise: Within allowable per ASTM E119 and CAN/ULC S101